An experiment to find thermocouple constant

in #steemstem7 years ago (edited)

Hello, Steemians! I Hope everyone is fine. Today, I will be discussing an experiment of calibration of the thermocouple.

Introduction

The accurate measurement of temperature is important in different fields. There are many methods to measure the temperature of various range. These measurement techniques depend upon the effect of temperature. The fluid expands when heated, this effect is used to make glass thermometer. Like this, the temperature difference between two dissimilar electrical conductors produces a voltage difference between the two conductors[1]. This is called Seebeck effect.


5585089524_6527e36794_z.jpg
wikimedia commons

The value of this voltage depends upon several factors including temperature. The pair of conductors of this sort is used to measure the temperature are called thermocouple. The produced voltage depends upon the type of thermocouple used. Higher the distance in thermoelectric series, higher is the voltage produced.


5585089524_6527e36794_z.jpg
Source: electronics cooling

For example, the maximum voltage is produced if the thermocouple is Antimony-Bismuth.

We need to know two more effects to understand this experiment.

Peltier is just the reverse effect of Seebeck effect. It is the presence of heating or cooling at an electrified junction of two different conductors. When a current is made to flow through a junction between two conductors A and B, heat may be generated (or removed) at the junction[2].

The major difference between Thomson effect and other two is that in Thomson effect we deal with only single metallic rod and not with thermo-couple as in Peltier effect and Seebeck effect[3].

According to this effect, if a conductor has placed in varying temperature along its length and current is passed through it then it will absorb or evolve heat. Absorbing or evolving heat will depend on the direction of the current.

Relevent Equation

Peltier effect,

eA-eB = P (ӨA – Ө B) … (1)
Here P is Peltier coefficient.

Thompson’s Effect,

e1 = T1 (ӨA- ӨB) … (i)
e2 = T2 (ӨA – ӨB) … (ii)

From (i) and (ii)
e2 – e1 = (T2-T1)(ӨA – ӨB) … (2)

T1 and T2 are Thompson coefficient.

From (1) and (2)

eA-eB + e2 – e1 = (P+ T2 –T1)(ӨA – ӨB)

or, E = k (ӨA – ӨB)

Here, E = eA- eB + e2 – e1

And, k = (P+ T2 –T1)

eA - eB = potential difference between A and B
ӨA – ӨB = temperature difference between A and B
k = thermocouple constant
e2-e1 = potential difference from thompson effect

The equipment and accessory required to carry out this experiment are as follows:

i) TK294A Instrumentation module
ii) Heat bar
iii) Thermometer
iv) Calibration Tank
v) Transducer thermocouple and flying compensating lead
vi) Power Supply
vii) Multi-meter

Observational Table

Notch NumberTank Temperature(in ℃)Room Temperature (in ℃)Temperature DifferenceVoltmeter Reading(in V)TC emf (in mV)
29527682.5200.002520
48027532.5120.002512
67127442.0000.002500
86527382.4870.002487
105927322.4810.002481
125427272.4710.002471
145027232.4570.002457
164527182.4490.002449
184227152.4460.002446
203827112.4110.002411
22342772.4000.002400

Result


5585089524_6527e36794_z.jpg
[thermocouple emf vs temperature difference](Drawn on excel)

The slope of the approximating line = 2e-6 mV/℃
= 2e-3 μV/℃
It is the thermocouple constant.

Discussion

In this experiment, we calibrated the thermocouple. We observed different values of emf produced for different differences between two junctions. The emf so produced was small, so we amplified and observed using a voltmeter. The graph was drawn between produced emf and difference in temperature. In actual, the curve should be linear but in our practice, it has deviated from it. An equivalent line was used to approximate the curve and slope was calculated.
The difference in the ideal condition and practical was due to human error, inaccuracy to measure temperature by thermometer to a required limit, the sensitivity of the instrument etc.

Conclusion

It was concluded that the emf produced is dependent on the difference in the temperature between two junctions. By the above method, we can observe and calculate such phenomenon. Thermocouple constant can be calculated.

References

  1. seebeck effect

  2. peltier effect

  3. thompson effect

Sort:  

Congratulations @thescienceguy! You have completed some achievement on Steemit and have been rewarded with new badge(s) :

Award for the number of posts published

Click on any badge to view your own Board of Honor on SteemitBoard.

To support your work, I also upvoted your post!
For more information about SteemitBoard, click here

If you no longer want to receive notifications, reply to this comment with the word STOP

Upvote this notification to help all Steemit users. Learn why here!

Coin Marketplace

STEEM 0.22
TRX 0.20
JST 0.034
BTC 99006.74
ETH 3331.65
USDT 1.00
SBD 3.09